    Air-insufflated high-definition dacryoendoscopy yields significantly better image quality than conventional dacryoendoscopy

     

    Authors Sasaki T, Sounou T, Tsuji H, Sugiyama K

    Received 21 February 2017

    Accepted for publication 18 May 2017

    Published 1 August 2017 Volume 2017:11 Pages 1385—1391

    DOI http://doi.org/10.2147/OPTH.S135234

    Checked for plagiarism Yes

    Review by Single-blind

    Peer reviewers approved by Dr Colin Mak

    Peer reviewer comments 3

    Editor who approved publication: Dr Scott Fraser

    Purpose: To facilitate the analysis of lacrimal conditions, we utilized high-definition dacryoendoscopy (HDD) and undertook observations with a pressure-controlled air-insufflation system. We report the safety and performance of HDD.
    Methods: In this retrospective, non-randomized clinical trial, 46 patients (14 males and 32 females; age range 39–91 years; mean age ± SD 70.3±12.0 years) who had lacrimal disorders were examined with HDD and conventional dacryoendoscopy (CD). The high-definition dacryoendoscope had 15,000 picture element image fibers and an advanced objective lens. Its outer diameter was 0.9–1.2 mm. Air insufflation was controlled at 0–20 kPa with a digital manometer-based pressure-controlled air-insufflation system to evaluate the quality of the image. The HDD had an air/saline irrigation channel between the outer sheath (outer diameter =1.2 mm) and the metal inner sheath of the endoscope. We used it and the CD in air, saline, and diluted milk saline with and without manual irrigation to quantitatively evaluate the effect of air pressure and saline irrigation on image quality.
    Results: In vivo, the most significant improvement in image quality was demonstrated with air-insufflated (5–15 kPa) HDD, as compared with saline-irrigated HDD and saline-irrigated CD. No emphysema or damage was noted under observation with HDD. In vitro, no significant difference was demonstrated between air-insufflated HDD and saline-irrigated HDD. In vitro, the image quality of air-insufflated HDD was significantly improved as compared with that of saline-irrigated CD.
    Conclusion: Pressure-controlled (5–15 kPa) air-insufflated HDD is safe, and yields significantly better image quality than CD and saline-irrigated HDD.
    Keywords: pressure-controlled air-insufflated, high-definition dacryoendoscopy, saline-irrigated dacryoendoscopy, emphysema


    摘要视频链接:Pressure-controlled air-insufflated high-definition dacryoendoscopy






    Download Article[PDF]